TY - JOUR
T1 - Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard
T2 - a retrospective study
AU - Awais, Muhammad
AU - Qamar, Saqib
AU - Rehman, Abdul
AU - Baloch, Noor Ul Ain
AU - Shafqat, Gulnaz
N1 - Publisher Copyright:
© 2018, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2019/6/1
Y1 - 2019/6/1
N2 - Purpose: Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. Methods: We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Results: Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29–53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Conclusion: Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.
AB - Purpose: Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. Methods: We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Results: Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29–53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Conclusion: Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.
KW - Computed tomography
KW - Contrast swallow
KW - Esophageal perforation
KW - Esophagography
KW - Fluoroscopy
UR - https://www.scopus.com/pages/publications/85042550212
U2 - 10.1007/s00068-018-0929-4
DO - 10.1007/s00068-018-0929-4
M3 - Article
C2 - 29484462
AN - SCOPUS:85042550212
SN - 1863-9933
VL - 45
SP - 517
EP - 525
JO - European Journal of Trauma and Emergency Surgery
JF - European Journal of Trauma and Emergency Surgery
IS - 3
ER -