Anaesthesia at remote location: Use of modified bain circuit (Mapleson D) at Kunri Christian Hospital (KCH)

Ehtesham Izhar Khan, Hameed Ullah, Rehana Kamal

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Objective: To develop a safe general anaesthesia technique for remote areas with lack of facilities. Methods: Four types of anaesthesia techniques using TIVA and modified Bain circuit were planned. Monitoring facility was limited to manual sphygmomanometer, palpation of radial pulse and monitoring of colour of skin and blood. Depth of anaesthesia was assessed using EVANs, RPST scoring system. Patients were asked in recovery room for awareness. Results: Surgeries done were cesarean sections, laparotomies, gynaecological, urological, hernia and burn contractures. Six patients had RPST score of 5 or more and three patients in recovery room complained of awareness. Cost per Anaesthesia was Rs225. Conclusion: TIVA with modified Bain circuit provided effective anaesthesia in remote area at low cost.

Original languageEnglish (UK)
Pages (from-to)445-448
Number of pages4
JournalJournal of the Pakistan Medical Association
Volume59
Issue number7
Publication statusPublished - Jul 2009

Fingerprint

Dive into the research topics of 'Anaesthesia at remote location: Use of modified bain circuit (Mapleson D) at Kunri Christian Hospital (KCH)'. Together they form a unique fingerprint.

Cite this