TY - JOUR
T1 - Assessing the diagnostic accuracy of postnatal clinical scoring methods and foot length measurement for estimating gestational age and birthweight of newborns in low- and middle-income countries
T2 - a systematic review and meta-analysis
AU - Tikmani, Shiyam Sunder
AU - Mårtensson, Thomas
AU - Khalid, Sumaira
AU - Uzair, Muhammad
AU - Ali, Qammerulanissa
AU - Rahim, Anum
AU - Mårtensson, Andreas
AU - Saleem, Sarah
AU - Brown, Nick
N1 - Publisher Copyright:
© Author(s) (or their employer(s)) 2024. Re-use permitted under CC BY. Published by BMJ.
PY - 2024/8/30
Y1 - 2024/8/30
N2 - Background This study aimed to update systematic reviews and meta-analyses on the diagnostic accuracy of postnatal clinical scoring (PCS) methods and foot length (FL) measurement for assessing gestational age (GA) and birth weight in low-income and middle-income countries (LMICs). In addition, the quality of reference standards, including antenatal ultrasound (A-US), last menstrual period (LMP), PCS and newborn weighing scales, was also evaluated. Methods Studies from LMICs published between January 2000 and February 2024 were searched, using databases such as PubMed, Web of Science, Cochrane Library, CINAHL and Scopus. Studies that compared PCS and/or FL with LMP and/or A-US to estimate GA or used calibrated newborn weighing scales for birthweight estimation were included. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-II tool and evaluated the quality of the reference standards. When sufficient data were available, pooled estimates were calculated using random-effects models. Results A total of 50 studies were included. A-US was a reasonable tool for GA assessment if conducted by physicians using fetal biometry and the Hadlock method for GA estimation. LMP was reasonable when women had regular cycles, knew their LMP, were not using contraceptives and LMP data were collected by healthcare providers. When A-US was used as the reference standard, PCS methods estimated GA with a precision of ±2.8 to ±3.2 weeks. FL measurement <7.5 cm showed a pooled sensitivity of 76.2% and specificity of 36.6% for identifying preterm birth. FL measurement ≤7.6 cm had a pooled sensitivity of 78.6% and specificity of 65.7% for identifying low birth weight (LBW). High heterogeneity across studies was observed. Conclusion This systematic review and meta-analysis highlights significant variability and methodological inconsistencies in using PCS methods and FL measurement for estimating GA and LBW in LMICs. The observed high heterogeneity across studies suggests a cautious interpretation of the results. PROSPERO registration number CRD42020209455.
AB - Background This study aimed to update systematic reviews and meta-analyses on the diagnostic accuracy of postnatal clinical scoring (PCS) methods and foot length (FL) measurement for assessing gestational age (GA) and birth weight in low-income and middle-income countries (LMICs). In addition, the quality of reference standards, including antenatal ultrasound (A-US), last menstrual period (LMP), PCS and newborn weighing scales, was also evaluated. Methods Studies from LMICs published between January 2000 and February 2024 were searched, using databases such as PubMed, Web of Science, Cochrane Library, CINAHL and Scopus. Studies that compared PCS and/or FL with LMP and/or A-US to estimate GA or used calibrated newborn weighing scales for birthweight estimation were included. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-II tool and evaluated the quality of the reference standards. When sufficient data were available, pooled estimates were calculated using random-effects models. Results A total of 50 studies were included. A-US was a reasonable tool for GA assessment if conducted by physicians using fetal biometry and the Hadlock method for GA estimation. LMP was reasonable when women had regular cycles, knew their LMP, were not using contraceptives and LMP data were collected by healthcare providers. When A-US was used as the reference standard, PCS methods estimated GA with a precision of ±2.8 to ±3.2 weeks. FL measurement <7.5 cm showed a pooled sensitivity of 76.2% and specificity of 36.6% for identifying preterm birth. FL measurement ≤7.6 cm had a pooled sensitivity of 78.6% and specificity of 65.7% for identifying low birth weight (LBW). High heterogeneity across studies was observed. Conclusion This systematic review and meta-analysis highlights significant variability and methodological inconsistencies in using PCS methods and FL measurement for estimating GA and LBW in LMICs. The observed high heterogeneity across studies suggests a cautious interpretation of the results. PROSPERO registration number CRD42020209455.
KW - Neonatology
UR - http://www.scopus.com/inward/record.url?scp=85206317050&partnerID=8YFLogxK
U2 - 10.1136/bmjpo-2024-002717
DO - 10.1136/bmjpo-2024-002717
M3 - Article
C2 - 39214548
AN - SCOPUS:85206317050
SN - 2399-9772
VL - 8
JO - BMJ Paediatrics Open
JF - BMJ Paediatrics Open
IS - 1
M1 - e002717
ER -