N2 - Respiration is an important vital sign which can help in the indication of human's health status. Sleep apnea, which is defined as a cessation of breathing while sleeping, is recognized as a common and critical popular health problem. By monitoring the patient's respiration rate, sleep apnea can be diagnosed. The received signal from the patient, which is a variation in temperature, is converted into a variation in voltage and then the respiration rate can be calculated. A portable device is proposed that can continuously monitor the breathing rhythm in a manner which is fast, safe and costly effective. The system consists of a nasal-oral thermistor that is mounted inside a nebulizer mask for detecting the irregular respiratory interruption and providing audible and visual alarms when this interrupt indicates an apnea event. Otherwise, if an out-of-range value occurred the alarm also will be initiated. Thus, the device will contribute to reducing the death associated with sleep apnea.
AB - Respiration is an important vital sign which can help in the indication of human's health status. Sleep apnea, which is defined as a cessation of breathing while sleeping, is recognized as a common and critical popular health problem. By monitoring the patient's respiration rate, sleep apnea can be diagnosed. The received signal from the patient, which is a variation in temperature, is converted into a variation in voltage and then the respiration rate can be calculated. A portable device is proposed that can continuously monitor the breathing rhythm in a manner which is fast, safe and costly effective. The system consists of a nasal-oral thermistor that is mounted inside a nebulizer mask for detecting the irregular respiratory interruption and providing audible and visual alarms when this interrupt indicates an apnea event. Otherwise, if an out-of-range value occurred the alarm also will be initiated. Thus, the device will contribute to reducing the death associated with sleep apnea.
KW - Nasal oral thermistor
KW - Nebulizer mask
KW - Respiratory monitoring system
KW - Respiratory rate
KW - Sleep apnea
UR - https://www.scopus.com/pages/publications/85133859576
U2 - 10.1109/IEMTRONICS55184.2022.9795832
DO - 10.1109/IEMTRONICS55184.2022.9795832
M3 - Conference contribution
AN - SCOPUS:85133859576
T3 - 2022 IEEE International IOT, Electronics and Mechatronics Conference, IEMTRONICS 2022
BT - 2022 IEEE International IOT, Electronics and Mechatronics Conference, IEMTRONICS 2022
A2 - Chakrabarti, Satyajit
A2 - Paul, Rajashree
A2 - Gill, Bob
A2 - Gangopadhyay, Malay
A2 - Poddar, Sanghamitra
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2022 IEEE International IOT, Electronics and Mechatronics Conference, IEMTRONICS 2022
Y2 - 1 June 2022 through 4 June 2022
ER -