TY - JOUR
T1 - Dynamic filling index
T2 - a novel parameter to monitor circulatory filling during minimized extracorporeal bypass
AU - Simons, Antoine P.
AU - Reesink, Koen D.
AU - Lancé, Marcus D.
AU - van der Veen, Frederik H.
AU - de Jong, Dick S.
AU - Weerwind, Patrick W.
AU - Maessen, Jos G.
PY - 2009/8
Y1 - 2009/8
N2 - Objective: To evaluate the dynamic filling index, a novel parameter to monitor changes in venous return and drainable volume, in circulatory assisted patients. Minimized extracorporeal bypass systems lack volume buffering capacity, demanding tight control of drainable volume to maintain bypass flow. Therefore, with patients on minimized bypass quantitative assessment of venous drainable volume is crucial. Methods: In seven patients undergoing coronary artery bypass grafting using minimized extracorporeal bypass we utilized luxation of the heart to induce a reduction in venous return. The speed of the centrifugal pump was transiently and periodically reduced to monitor resultant changes in bypass flow. The dynamic filling index, a measure of drainable volume, was calculated as Δflow/Δspeed. Results: With luxation, the dynamic filling index was significantly reduced (from 2.4 ± 0.2 to 2.0 ± 0.2 ml/rotation, p = 0.001; 95% confidence interval of mean difference: 0.23-0.46 ml/rotation), whereas routinely recorded parameters, like bypass flow, pump inlet and arterial line pressure, did not change significantly. The intra-measurement reproducibility for the dynamic filling index was 0.5 ml/rotation (20% of the mean), suggesting good potential for this parameter to monitor on-pump venous return in patients. Conclusion: The dynamic filling index can detect small changes in venous return and drainable volume which remain unrevealed by routinely recorded parameters. This index could be a valuable tool to monitor and control circulatory filling in individual patients supported by minimized extracorporeal bypass.
AB - Objective: To evaluate the dynamic filling index, a novel parameter to monitor changes in venous return and drainable volume, in circulatory assisted patients. Minimized extracorporeal bypass systems lack volume buffering capacity, demanding tight control of drainable volume to maintain bypass flow. Therefore, with patients on minimized bypass quantitative assessment of venous drainable volume is crucial. Methods: In seven patients undergoing coronary artery bypass grafting using minimized extracorporeal bypass we utilized luxation of the heart to induce a reduction in venous return. The speed of the centrifugal pump was transiently and periodically reduced to monitor resultant changes in bypass flow. The dynamic filling index, a measure of drainable volume, was calculated as Δflow/Δspeed. Results: With luxation, the dynamic filling index was significantly reduced (from 2.4 ± 0.2 to 2.0 ± 0.2 ml/rotation, p = 0.001; 95% confidence interval of mean difference: 0.23-0.46 ml/rotation), whereas routinely recorded parameters, like bypass flow, pump inlet and arterial line pressure, did not change significantly. The intra-measurement reproducibility for the dynamic filling index was 0.5 ml/rotation (20% of the mean), suggesting good potential for this parameter to monitor on-pump venous return in patients. Conclusion: The dynamic filling index can detect small changes in venous return and drainable volume which remain unrevealed by routinely recorded parameters. This index could be a valuable tool to monitor and control circulatory filling in individual patients supported by minimized extracorporeal bypass.
KW - Blood volume
KW - Cardiopulmonary bypass
KW - Centrifugal pump
KW - Minimized extracorporeal bypass
KW - Venous drainage
KW - Venous return
UR - http://www.scopus.com/inward/record.url?scp=67650047870&partnerID=8YFLogxK
U2 - 10.1016/j.ejcts.2009.03.045
DO - 10.1016/j.ejcts.2009.03.045
M3 - Article
C2 - 19411180
AN - SCOPUS:67650047870
SN - 1010-7940
VL - 36
SP - 330
EP - 334
JO - European Journal of Cardio-thoracic Surgery
JF - European Journal of Cardio-thoracic Surgery
IS - 2
ER -