Abstract
The synthesis of 188Re-MAG3 is described using 188Re, which was obtained from the alumina based 188W/188Re generator. Dependence of the radiolabeling yields of 188Re-MAG3 on reducing agent concentration, Bz-MAG3 concentration, pH, temperature and incubation time was examined. In the case of optimum conditions the yield of 188Re-MAG3 was 98%. TLC and HPLC techniques were employed to monitor the different species formed Biodistribution study of 188Re-MAG3 was carried out in rats and compared with behavior of 99mTC-MAG3.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 421-424 |
| Number of pages | 4 |
| Journal | Journal of Radioanalytical and Nuclear Chemistry |
| Volume | 257 |
| Issue number | 2 |
| DOIs | |
| Publication status | Published - 1 Aug 2003 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Fingerprint
Dive into the research topics of 'Formulation of a freeze-dried kit for 188Re-MAG3 and its quality control'. Together they form a unique fingerprint.Cite this