Radiation exposure of trainee anaesthetists

S. Ismail, Fauzia A. Khan, N. Sultan, M. Naqvi

Research output: Contribution to journalArticlepeer-review

16 Citations (Scopus)

Abstract

This prospective study was conducted to determine the level of radiation exposure of trainee anaesthetists working in urology, orthopaedics and radiology environments. Anaesthetists wore lithium fluoride thermoluminescent dosimeter (TLD) badges over a 6-month period. The position of badges was standardised at the collar site (TLD1) and at waist level (TLD2). Area specific dosimeters were used and exchanged between anaesthetists. Of a total of 723 procedures, anaesthetists were exposed to radiation in 33% of procedures in orthopaedics, 30% in urology and 39% in radiology. The mean (SD) exposure time to radiation per case was significantly greater in orthopaedics than in urology (9.2 (4) min vs. 4.2 (2) min). The radiation exposure per case was highest in radiology (19.2 (22) min). The net combined exposure over a 6-month period was 0.2177 mSv in urology, 0.4265 mSv in orthopaedics and 3.8457 mSv in radiology. The combined exposure was less than the 20 mSv recommended as the maximum exposure per year. Our data does not support the need for routine dosimetric monitoring of anaesthetists working in the above settings.

Original languageEnglish
Pages (from-to)9-14
Number of pages6
JournalAnaesthesia
Volume61
Issue number1
DOIs
Publication statusPublished - Jan 2006
Externally publishedYes

Fingerprint

Dive into the research topics of 'Radiation exposure of trainee anaesthetists'. Together they form a unique fingerprint.

Cite this