TY - JOUR
T1 - Stability and sterility of a recombinant factor VIII concentrate prepared for continuous infusion administration
AU - Belgaumi, Asim F.
AU - Patrick, Christian C.
AU - Deitcher, Steven R.
PY - 1999
Y1 - 1999
N2 - Minipumps may facilitate cost-effective and convenient continuous infusion (CI) therapy for severe hemophilia A. This study evaluated the in vitro sterility, ability to support bacterial growth, and specific activity stability of a recombinant factor VIII (FVIII; Bioclate(TM), Centeon) delivered by simulated CI at a variety of temperatures and after the addition of heparin or antibiotic. Closed system CIs of Bioclate(TM) (89.5 IU/ml) with and without heparin were sampled and cultured over a 6 day period. Bioclate(TM) (53.7 IU/ml) with and without heparin or vancomycin was inoculated with 102-105 CFU/ml of S. aureus, S. epidermidis, Escherichia coli, E. cloacae, or Y. enterocolitica and assessed by quantitative culture after 1 and 3 days. The stability of Bioclate(TM) (50, 100, and 250 IU/ml) at three temperatures (21°C, 37°C, and 39°C) with and without heparin or vancomycin was tested over a period of 28 days. FVIII activity was measured in triplicate by a chromogenic assay (Coamatic® Factor VIII, Chromogenix) and purity evaluated by Western blot. No bacterial growth was detected during CI of FVIII for up to 6 days. Following bacterial inoculation, there was rapid growth (>3 log increase) of all tested bacterial species except S. aureus which only displayed a 1 log expansion at 3 days. The addition of heparin containing 9.45 μg/U benzyl alcohol had no effect on bacterial growth. The addition of vancomycin caused a modest suppression of S. aureus growth but not of E. coli. Diluent alone did not support bacterial growth. Neither concentration, increased temperature, nor the addition of heparin or vancomycin had a significant effect on FVIII activity stability. Samples retained >75% baseline activity for between 3 and 7 days, except the infusion of Bioclate(TM) 50 IU/ml plus heparin maintained at 21°C which remained stable for 28 days. Western blot analysis supported the activity assay findings. Standard and concentrated preparations of Bioclate(TM) are suitable for CI when delivered by the MiniMed® 404-SP minipump. Because of the observed nutritive capability of this FVIII concentrate for sustaining bacterial growth, any contamination could result in systemic infection.
AB - Minipumps may facilitate cost-effective and convenient continuous infusion (CI) therapy for severe hemophilia A. This study evaluated the in vitro sterility, ability to support bacterial growth, and specific activity stability of a recombinant factor VIII (FVIII; Bioclate(TM), Centeon) delivered by simulated CI at a variety of temperatures and after the addition of heparin or antibiotic. Closed system CIs of Bioclate(TM) (89.5 IU/ml) with and without heparin were sampled and cultured over a 6 day period. Bioclate(TM) (53.7 IU/ml) with and without heparin or vancomycin was inoculated with 102-105 CFU/ml of S. aureus, S. epidermidis, Escherichia coli, E. cloacae, or Y. enterocolitica and assessed by quantitative culture after 1 and 3 days. The stability of Bioclate(TM) (50, 100, and 250 IU/ml) at three temperatures (21°C, 37°C, and 39°C) with and without heparin or vancomycin was tested over a period of 28 days. FVIII activity was measured in triplicate by a chromogenic assay (Coamatic® Factor VIII, Chromogenix) and purity evaluated by Western blot. No bacterial growth was detected during CI of FVIII for up to 6 days. Following bacterial inoculation, there was rapid growth (>3 log increase) of all tested bacterial species except S. aureus which only displayed a 1 log expansion at 3 days. The addition of heparin containing 9.45 μg/U benzyl alcohol had no effect on bacterial growth. The addition of vancomycin caused a modest suppression of S. aureus growth but not of E. coli. Diluent alone did not support bacterial growth. Neither concentration, increased temperature, nor the addition of heparin or vancomycin had a significant effect on FVIII activity stability. Samples retained >75% baseline activity for between 3 and 7 days, except the infusion of Bioclate(TM) 50 IU/ml plus heparin maintained at 21°C which remained stable for 28 days. Western blot analysis supported the activity assay findings. Standard and concentrated preparations of Bioclate(TM) are suitable for CI when delivered by the MiniMed® 404-SP minipump. Because of the observed nutritive capability of this FVIII concentrate for sustaining bacterial growth, any contamination could result in systemic infection.
KW - Continuous infusion
KW - Factor VIII
KW - Hemophilia
KW - Minipumps
KW - Prophylaxis
UR - https://www.scopus.com/pages/publications/0032882274
U2 - 10.1002/(SICI)1096-8652(199909)62:1<13::AID-AJH3>3.0.CO;2-X
DO - 10.1002/(SICI)1096-8652(199909)62:1<13::AID-AJH3>3.0.CO;2-X
M3 - Article
C2 - 10467271
AN - SCOPUS:0032882274
SN - 0361-8609
VL - 62
SP - 13
EP - 18
JO - American Journal of Hematology
JF - American Journal of Hematology
IS - 1
ER -